1. Obtain the maximum horizontal tubing length (L ) from Tables .
2. Take 3% of the maximum horizontal tubing length (L) in meters and multiply the result by the vertical distance (Lvert):
C = 0.03 x (L) x (L vert)
3. Subtract this product (C) from the maximum horizontal tubing length (L) to obtain the maximum pumping distance (Lmax) in consideration of the specific vertical lift:
Note: The result is the maximum pumping distance (Lmax), including horizontal and vertical tubing runs, that is obtainable for the particular flow rate, tubing I.D. and viscosity of syrup specified.
To calculate the losses in the system in feet obtained the maximum horizontal tubing length in feet and multiply by 1% instead of 3%.
|